The environmental monitoring data center
Used in the data center temperature and humidity control precision and stability of instruments
Download guide about how to make the data center to maintain good operationPrecision stability of the instrument is the key to maintain appropriate temperature and humidity levels
For a need to rely on the success of the company software in the operation of the high efficiency and reliable, data center is the brain of the company.Because the focus in one place many powerful hardware, data center must keep the appropriate temperature, and the effects of external and internal environment.In view of the data center will consume a large amount of energy, how can we improve the energy efficiency and PUE (power efficiency)?
Measuring correctly.Reduce cooling costs correctly one important requirement is the start of the measurement of environmental conditions.The success of your data center temperature control strategy depends on your measurement device, even a small error of measurement will also make your energy costs increased significantly.
Wisely to carry on the design.For example, you can benefit from the air side economizer or evaporative cooler?For the instrument to select the correct humidity parameters, and select the specially designed for the position of the need to measure the specific instruments.
The instrument is in good condition.Instruments need to be check regularly.Choose long-term drift smallest instruments and easy to maintain, and specifies the reliable service for your data center and calibration plan.
Improve your profitability by data-driven decisions
Demand for increasing capacity and speed is to promote the development of industry data center and optimization, which makes in the specific environment conditions can reliable operation of instrument equipment has been adopted.The escalating demand and the demand for continuous and uninterrupted operation together.With the help of a sensor network, operators can continuously monitor environmental conditions, so as to provide security for the customer.
Realize the uptime
Along with the increasing demand of data, for data center uptime expected value increases.Keep your data center is suitable for the temperature to keep normal running time is very important in a higher level, accurate hvac measurements can help you to do this.
By measuring the outdoor temperature and humidity conditions to optimize the indoor conditions
Through a variety of ways to make data center in a suitable temperature, depending on the location and the local climate.Refrigerant cooling will consume a large amount of energy, but it can be to optimize the consumption by considering local climate change.WXT530 meteorological series transmitter can help optimize indoor operating conditions.They can be integrated with your data center control system.
Understand our expert opinions
Through our free on-demand webinar and learn how to improve data center cooling process, and how to increase the server room revenue and efficiency, at the same time to reduce downtime and maintenance.
To ensure the reliability, consistency and accuracy
Key environment requires high performance of the environmental monitoring and measurement, to ensure continuous operation and conform to the specifications.Due to data center need round-the-clock operation, thus are not allowed to fail.Even a small error of measurement will be significantly increased the cost of energy.Reliable sensor can change the status quo.
Easy to maintain
- Easy to perform on-site inspection
- Replaceable probe
- All calibration services
Good accuracy and stability
- Precise control
- Good stability
- The total cost is low
After the factory calibration
- Excellent sensor technology
- The accuracy of the test
- Traceable calibration certificate
Related products
TMI110 immersion temperature transmitter
The immersion temperature transmitter TMI110 designed for high precision automation of hvac system in the process of cooling/heating water temperature and design.The transducer response speed, can be accurate and reliable control of the hvac system.
Indigo500 series data processing unit
Visa pull Indigo500 data processing unit is suitable for visa Indigo compatible with independent intelligent probe host devices.Indigo500 series including multifunctional Indigo520 data processing unit and has the basic function of Indigo510 data processing unit.
Temperature and humidity transmitter HMT120/130
HMT120 and HMT130 transmitter is suitable for clean room, museum, laboratory and data centers.Because of the intelligent measuring probe field replaceable, keep the measurement traceability is very easy.
Temperature and humidity transmitter HMDW110 series
Visa pull HUMICAP ® HMDW110 humidity and temperature transmitter series can be used for a variety of relative humidity and temperature measurement in hvac applications.This series of products including pipe installation type level transmitter, IP65 metope installed type transducer and outdoor transmitter is equipped with integrated radiation shield.
Temperature and humidity transmitter HMW90 series
Typical applications include museums and archives, the production and storage facilities, data centers, laboratories and test environment.
Temperature and humidity transmitter HMD60
Solid and reliable pipe installation type visa pull HUMICAP ® series humidity transmitter HMD60 specially designed for use in the demanding hvac measuring relative humidity and light industrial applications.Accurate, stable and reliable performance to make the products be ideal for demanding applications.
The probe HMP3 intelligent humidity and temperature
Visa pull HUMICAP®Intelligent humidity and temperature probe HMP3 designed for use with moderate humidity and temperature level of the general environment..
Temperature and humidity sensor HMP1
Visa pull HUMICAP ® temperature and humidity measuring probe HMP1 design for indoor space environment.
For more information, please contact us
Interested in details about our data center solutions products?Please leave a message to us, we will contact with you!